    Here we describe a protocol for extracting and quantifying bulk RNA and DNA from microalgae, which is adapted from Berdalet E. et al. (2005).

    RNA and DNA are extracted from microalgae samples and then quantified by fluorochrome SYBR Green II.

    The level of sensitivity of this method is set at ca. 20 ~300 ng RNA and 10 ~ 100 ng DNA (ml assay)-1.

    Citation
    Berdalet E, Roldán C, Olivar MP, Lysnes K Quantifying RNA and DNA in planktonic organisms with SYBR Green II and nucleases. Part A. Optimisation of the assay Scientia Marina http://doi.org/10.3989/scimar.2005.69n11

    Citation
    Berdalet E, Roldán C, Olivar MP Quantifying RNA and DNA in planktonic organisms with SYBR Green II and nucleases. Part B. Quantification in natural samples Scientia Marina http://doi.org/10.3989/scimar.2005.69n117

    Before start

    Steps

    Day 1: Freeze-dry samples

    1.

    Freeze dry samples and blank filters. Freeze at -80°C until processed.

    Note
    Freeze-drying should be as short as possible to reduce sample degradation.The exact duration of freeze-drying depends on size of filter, quantity of sample and the size of container.

    Equipment

    ValueLabel
    FreeZone® 2.5 L Benchtop Freeze DryersNAME
    Labconco®BRAND
    700202000SKU

    Day 1: Prepare primary solutions

    2.

    Turn on UV light in biosafety cabinet for 0h 15m 0s

    3.

    Clean working surface with decontamination solution.

    4.

    Prepare Tris buffer 5mM 8.0

    4.1.

    Pour 1M 8.0 Tris into an RNase free 15 mL Falcon tube

    Equipment

    ValueLabel
    Falcon® Centrifuge TubesNAME
    Polypropylene, Sterile, 15 mLTYPE
    Corning®BRAND
    352096SKU
    4.2.

    Directly add 2.5mL 1M``8.0 Tris into 500 mL RNase free water in its original package.

    Equipment

    ValueLabel
    BT Barrier Pipet TipsNAME
    Pre-SterileTYPE
    Neptune®BRAND
    BT1250, BT100, BT10SKU
    5.

    RNA primary standard solution (200ug/ml )

    5.1.

    In the original package, the frozen E. Coli Total RNA is of 1 mg/mL, in which total RNA is 200 ug.

    Note
    http://assets.thermofisher.com/TFS-Assets/LSG/manuals/sp_7940.pdf

    5.2.

    Uncap the original package of E. Coli Total RNA and directly add 800µL Tris buffer (5mM ,8.0) .

    Cap the package and vortex for a thorough mix.

    5.3.

    Aliquot 30 uL by stepper with sterile tip to 600 uL RNase free microtubes. Keep frozen at -80°C

    Equipment

    ValueLabel
    Finnpipette Stepper PipetteNAME
    Thermo Scientific™BRAND
    4540000SKU
    http://www.fishersci.com/us/en/home.htmlLINK

    Equipment

    ValueLabel
    Finntip stepper pipette tipsNAME
    500 ul (sterile)TYPE
    Thermo ScientificBRAND
    Thermo Scientific™ 9404173SKU
    http://www.fishersci.com/us/en/home.htmlLINK
    6.

    DNA primary standard solution (≈ 500ug/ml)

    6.1.

    Uncap the original package of Deoxyribonucleic acid from calf thymus and add 2mL Tris buffer (5mM ,8.0).

    Note
    http://www.sigmaaldrich.com/content/dam/sigma-aldrich/docs/Sigma/Product_Information_Sheet/d4522pis.pdf

    6.2.

    Cap the package. Do not vortex or sonicate.

    6.3.

    Keep the solution at 0°C ~4°C overnight to completely solubilize the DNA. Gentle reversion is recommended.

    6.4.

    Aliquot 10 uL by stepper with sterile tip to 600 uL RNase free microtubes. Keep frozen at -80°C

    Equipment

    ValueLabel
    Finntip stepper pipette tipsNAME
    500 ul (sterile)TYPE
    Thermo ScientificBRAND
    Thermo Scientific™ 9404173SKU
    http://www.fishersci.com/us/en/home.htmlLINK
    7.

    RNase primary stock solution (10mg/ml )

    7.1.

    Uncap the original package of Ribonuclease A from bovin pancreas and add 5mL Tris buffer (5mM ,8.0). Cap the package and vortex for a thorough mix.

    7.2.

    Aliquot 30 uL by stepper with sterile tip to 600 uL RNase free microtubes. Keep frozen at -20°C

    Equipment

    ValueLabel
    Finntip stepper pipette tipsNAME
    500 ul (sterile)TYPE
    Thermo ScientificBRAND
    Thermo Scientific™ 9404173SKU
    http://www.fishersci.com/us/en/home.htmlLINK

    Equipment

    ValueLabel
    Finntip™ Stepper Pipette TipsNAME
    500 ul (Sterile)TYPE
    Thermo ScientificBRAND
    21-377-149SKU
    http://www.fishersci.com/us/en/home.htmlLINK
    8.

    DNase primary stock solution (5mg/ml = 10,000 U/mL)

    8.1.

    Uncap the original package of Deoxyribonuclease1 and add 1mL Tris buffer (5mM ,8.0) .Cap the package and vortex for a thorough mix.

    8.2.

    Aliquot 70 uL to 600 uL RNase free microtubes (every assay required 60 uL). Keep frozen at -20°C.

    Day 2: Exact RNA and DNA

    9.

    Turn on UV light in biosafety cabinet for 0h 15m 0s

    10.

    Clean working surface with decontamination solution.

    11.

    Prepare falcon tubes and tube rack in biosafety cabinet| A | B | | --- | --- | | 5 | 0.5 M EDTA | | 5 | 20% sarcosine | | 50 | 5 mM Tris | | 15 or 50 | 1% STEB |

    Equipment

    ValueLabel
    Falcon® Centrifuge TubesNAME
    Polypropylene, Sterile, 15 mLTYPE
    Corning®BRAND
    352096SKU

    Equipment

    ValueLabel
    Falcon® Centrifuge TubesNAME
    Polypropylene, Sterile, 50 mLTYPE
    Corning®BRAND
    352070SKU
    12.

    Prepare STEB (1% )

    Note
    Use the following formula to determine the total volume of 1% STEB required:(# samples + # blank filters) X (500 ul) + (500 ul) = total volume of 1% STEB required

    12.1.

    Pour sarcosine (20% ) into an RNase free 5 mL falcon tube.

    12.2.

    Pour EDTA (0.5M ) into an RNase free 5 mL falcon tube.

    12.3.

    Pour Tris buffer (5mM ,8.0) into an RNase free 50 mL falcon tube.

    12.4.

    Mix 500µL sarcosine (20% ) , 10µL EDTA (0.5M ) and 9mL+490µL Tris buffer (5mM ,8.0) to obtain STEB (1% ).

    13.

    Prepare ice bath

    14.

    Remove freeze-dried samples from -80ºC freezer and place them On ice.

    15.

    Add 500µL Tris buffer (5mM ,8.0) and 500µL STEB (1% ) to the bead tube. Place tubes On ice.

    Equipment

    ValueLabel
    LYSING TUBESNAME
    MATRIX D 2 mL/15 mLTYPE
    MP BIOMEDICALSBRAND
    116913500/116933050SKU
    16.

    Rinse forceps by 70% volume ethanol and air dry.

    Equipment

    ValueLabel
    Filter forcepsNAME
    blunt end, stainless steelTYPE
    MilliporeBRAND
    XX6200006PSKU
    http://www.emdmillipore.com/LINK
    17.

    Transfer sample/blank filter into the bead tube by using clean forceps.

    18.

    Invert immediately then put back On ice.

    19.

    Disrupt samples on the bead mill at 6.5 m/s. Equipment

    ValueLabel
    Fastprep-24 5G™ Sample Preparation InstrumentNAME
    MP BiomedicalsBRAND
    116005500SKU
    20.

    Keep tubes On ice. Check the label on each tube, restore the label if it fades.

    21.

    Disrupt samples on the bead mill at 6.5 m/s.

    22.

    Keep tubes On ice. Check the label on each tube, restore the label if it fades.

    23.

    Disrupt samples on the bead mill at 6.5 m/s

    24.

    Keep tubes On ice. Check the label on each tube, restore the label if it fades.

    25.

    Disrupt samples on the bead mill at 6.5 m/s.

    26.

    Continuously shake homogenate in a multi-head vortex at the highest speed for 1h 0m 0s Room temperature

    Note
    Votex mixer should be able to remain stable on the bench under this vortex speed.

    27.

    In the biosafety cabinet, transfer all homogenate into RNase free 2 mL micro-tube.

    28.

    Freeze at -80°C until analyzed.

    Day 3: Run the assay

    29.

    Prepare ice bath.

    30.

    Turn on UV light in biosafety cabinet for 0h 15m 0s

    31.

    Clean working surface with decontamination solution.

    32.

    Prepare falcon tubes, microtubes and tube racks in biosafety cabinet| A | B | C | | --- | --- | --- | | 5 | 5 mL falcon tubes | 1 M MgCl2 | | | | 1 M CaCl2 | | | | Working solution A (WS-A) | | | | Working solution B (WS-B) | | | | Working solution C (WS-C) | | 1 | 50 mL falcon tube | 5 mM Tris buffer | | 1 | 15 mL falcon tubes | 0.05% STEB | | 6 | 2 mL RNase free tubes | RNase working solution | | | | RNA secondary standard solution | | | | DNA tertiary standard solution | | | | 900 mM MgCl2 | | | | 900 mM CaCl2 | | | | Sybr green working solution (SG-II WS) | | 1 | 600 uL RNase free tube | DNA secondary standard | | 24 | 2 mL RNase free tubes | RNA standard solutions for RNA standard curves | | | | DNA standard solutions for DNA standard curves | | N= total number of samples and blanks | 2 mL RNase free tubes | Samples and blanks | | 3XN | 2 mL RNase free tubes | Diluted samples and blanks | | 4 | Microtube racks | Tubes of 2 mL in Set 1 | | | | Tubes of 2 mL in Set A | | | | Tubes of 2 mL in Set B | | | | Tubes of 2 mL in Set C | | 1 | Tube racks | Falcon tubes |

    Equipment

    ValueLabel
    Screw-Cap Centrifuge TubeNAME
    5 mLTYPE
    VWRBRAND
    10002-738SKU

    Day 3: Run the assay (Caution: It is a long procedure!)

    33.

    Organize and label the tubes as shown below

    Set 1:

    In microtube rack, label 2 mL tubes for samples and blanks to be further diluted.

    Set A, B and C:

    In microtube rack, label 2 mL tubes for RNA (marked in pink), DNA (marked in blue) standard solutions and samples (marked in yellow)

    Set A is for working solution A (WS-A) treatment, i.e. treated with DNase

    Set B is for working solution B (WS-B) treatment, i.e. treated with RNase

    Set C is for working solution A (WS-A) and C (WS-C) treatment, i.e. treated with DNase and RNase

    34.

    Label tubes for reagents as following.

    Follow the sheet, add Tris buffer (5mM ,8.0) to the reagent tubes:

    AB
    SG-II WS1000+250
    WS-A2X1000+820
    WS-B2X1000+820
    WS-C2X1000+940
    RNase380
    900 mM MgCl240
    900 mM CaCl240
    RNA secondary990+495
    DNA secondary95
    DNA tertiary960
    0.05% STEB9X1000 + 500
    35.

    Thaw Sybr green II at room temperature

    36.

    Add 900µL Tris buffer (5mM ,8.0) to each tube in Set 1

    Note
    Depending on the dilution of extracted sample

    37.

    Follow the sheet, add Tris buffer (5mM ,8.0) to each tube in Set A, B and C . The unit of volume is uL.

    38.

    Prepare STEB (0.05% )

    Add 500µL STEB (1% ) to 0.05% STEB tube, and vortex.

    39.

    Add 250µL STEB (0.05% ) to RNA and DNA standards in Set A, B and C by reverse pipetting.

    40.

    Place RNase and DNase primary stock solutions, RNA and DNA primary standard solutions and samples -20On ice.

    41.

    Turn on refrigerated centrifuge and set the temperature to 4°C. Equipment

    ValueLabel
    CENTRIFUGE 5430 RNAME
    EppendorfBRAND
    MP2231000510SKU
    42.

    Turn on shaker/incubator and set temperature to 37°C.

    Equipment

    ValueLabel
    SHAKING INCUBATORNAME
    71LTYPE
    Corning® LSE™BRAND
    6753SKU
    43.

    Prepare 900mM MgCl2

    43.1.

    Pour 1M MgCl2solution into 5 mL RNase free Falcon tube

    43.2.

    Transfer 360µL 1M MgCl2solution into 900 mM MgCl2tube

    44.

    Add 60µL 900mM MgCl2 to WS-A

    45.

    Add 60µL 900mM MgCl2 to WS-B

    46.

    Prepare 900mM CaCl2

    46.1.

    Pour 1M CaCl2solution into 5 mL RNase free Falcon tube

    46.2.

    Transfer 360µL 1M CaCl2solution into 900 mM CaCl2tube

    47.

    Add 60µL 900mM CaCl2 to WS-A

    48.

    Add 60µL 900mM CaCl2 to WS-B

    49.

    Prepare SG-II WS

    49.1.

    Centrifuge one tube of SG-II concentrate at Room temperature 13000rpm to deposit DMSO.

    49.2.

    Wrap SG-II WS tube with foil, transfer supernatant supernatant of SYBR Green II 10,000X concentrate to SG-II WS tube in biosafety cabinet ( 8.75ul per 1.25 mL Tris)

    Note
    Any step involving SYBR Green II should be operated in dark room or at least dim light. Prepare Sybr green II WS at this step to allow enough time for stabilization.

    50.

    Note
    Lunch break!

    51.

    Prepare RNase working solution 0.5mg/ml

    Add 20µL RNase primary stock solution (10mg/ml) to RNase tube

    52.

    Add 60µL 0.5mg/ml RNase to WS-B.

    Keep WS-B 37On ice .

    53.

    Add 60µL 0.5mg/ml RNase to WS-C.

    Keep WS-C 37On ice .

    54.

    Add 60µL DNase primary stock solution ( 5mg/ml ) to WS-A.

    Keep WS-A 37On ice.

    55.

    Centrifuge extracted samples 10000x g,4°C

    56.

    Prepare RNA secondary standard solution 2ug/ml

    Add 15µL RNA primary standard solution to RNA standard tube and mix.

    Keep 37On ice .

    57.

    Prepare DNA secondary standard solution (25ug/ml)

    Add 5µL primary DNA standard solution (500ug/ml) to DNA secondary tube and mix.

    Note
    DNA secondary standard will also be used to verify the actual concentration of DNA by using μdrop plate.

    Note
    Avoid vortexing DNA standard. Mix with pipette tip by aspiring up and down several times.

    58.

    Prepare DNA tertiary standard solution 1ug/ml

    Add 40µL DNA secondary solution (25ug/ml) to DNA tertiary standard tube and mix.

    Keep 37On ice.

    59.

    Load 50µL WS-A to tubes in Set A .

    Note
    From 59 to 62: Reverse pipettingDecontaminate pipet between different WS.

    60.

    Load 50µL WS-A to tubes Set C .

    61.

    Load 50µL WS-B to tubes in Set B .

    62.

    Load 50µL WS-C to tubes in Set C .

    63.

    Add 100µL centrifuged samples to its corresponding tubes in Set 1 .

    Gently invert the tube to mix sample.

    64.

    From Set 1, transfer 250µL of diluted samples to each corresponding tubes (marked in yellow) in Set A, B and C .

    Add RNA secondary standard to tubes (marked in pink) in Set A, B and C .

    Add DNA secondary standard to tubes (marked in blue) in Set A, B and C .

    The unit of volume is uL.

    Note
    In order to avoid cross contamination from RNase or DNase, use one tip for each dispensing.Pipette solution in the tube up and down for mixing.

    65.

    Invert each tube to mix well and place all tubes into the shaker/incubator at 37°C, continuously shaking at 200 RPM for 0h 20m 0s.

    Note
    Incubation time is critical. Temperature might be disturbed by door open/close. Don't start the timer until temperature returns to 37°C.

    66.

    After incubation, invert each tube for mixing and then place into the fridge to stop the reaction.

    Day 3: Verify DNA concentration and SG-II absorbance

    67.

    Measure DNA secondary concentration by using μdrop plate (sample volume: 4 ul)

    Use Tris buffer (5mM ,8.0) as blank.

    Equipment

    ValueLabel
    µDrop™ PlatesNAME
    Thermo ScientificBRAND
    N12391SKU
    http://www.lifetechnologies.comLINK

    Equipment

    ValueLabel
    Varioskan LUX Multimode Microplate ReaderNAME
    Thermo FisherBRAND
    VL0L00D0SKU
    68.

    DNA_primary concentration (μg/ml) = (Abs260-Abs260 (blank))x 50 μg/ml x (10mm/0.5 mm) X DF

    Where, DF=20

    Note
    The DNA concentration is around 500 ug/mL but can be much lower (since the small volume of DNA primary aliquot is hard to be mixed), use the measured DNA value to calculate the DNA primary concentration.

    69.

    Check absorbance of SG-II WS:

    69.1.

    In a transparent microplate, load

    (1) 200 uL Tris buffer as blank

    (2) 10 uL SG-II WS and 190 uL Tris buffer

    69.2.

    Read absorbance at 480 nm, the value after subtracted by blank shall be no higher than 0.21

    Day 3: Read fluorescence

    70.

    Remove samples out of the fridge and allow to reach Room temperature for 0h 2m 0s before loading the microplate.

    Note
    Since fluorescence decreases with increasing temperature, with percentage changes depending on the fluorophore (Bashford, 1987), the SG-II WS must be kept dark at RT (22ºC) and the samples must be equilibrated at RT (c. 2 min).

    71.

    Adhere black film on the top of a microplate lid.

    Equipment

    ValueLabel
    Black Vinyl Films for Fluorescence and PhotoprotectionNAME
    VWRBRAND
    89087-692SKU

    Equipment

    ValueLabel
    Microplate LidsNAME
    PolystyreneTYPE
    Greiner Bio-OneBRAND
    07000288SKU
    http://www.fishersci.com/us/en/home.htmlLINK
    72.

    Load 10µL SG-II WS to each well in the microplate with 0.5 mL tip of stepper, and cover the plate with the black-film lid.

    Equipment

    ValueLabel
    Finntip™ Stepper Pipette TipsNAME
    500 uLTYPE
    Thermo Scientific™BRAND
    9404170SKU
    http://www.fishersci.com/us/en/home.htmlLINK

    Equipment

    ValueLabel
    96-Well Black MicroplatesNAME
    PolystyreneTYPE
    Greiner Bio-OneBRAND
    655076SKU

    Note
    Wipe or dab the liquid drop on the outside of the tip, avoid wiping the tip open before dispensing the liquid.

    73.

    Organize tubes in 96-well microtube rack in the same order as how microplates are loaded.

    74.

    Load 190µL working sample to the microplate by reverse pipetting.

    Note
    Wipe or dab the liquid drop on the outside of the tip, avoid wiping the tip open before dispensing the liquid.

    75.

    Shake black film covered microplate at 37Room temperature for 1h 30m 0s

    Note
    Read fluorescence right after 1h30 incubation at room temperature.

    76.

    Setup microplate reader:Plate: Greiner F bottom chimney well PP 96 well;Shake: Continuous 5s at 600 rpmBandwidth: 5 nmEndpoint reading: Ex 490 nm/Em 520 nm; Equipment

    ValueLabel
    Varioskan LUX Multimode Microplate ReaderNAME
    Thermo FisherBRAND
    VL0L00D0SKU
    77.

    Read fluorescence and export data to excel sheet.

    78.

    In the fume hood, dispose any waste with SG-II into fluorescence stain waste container (some stain waste has DMSO solvent).

    Calculate

    79.

    RNA standard curve

    79.1.

    Concentrations of RNA standards in the microplate

    ABCDEFGH
    R10.00650.00250.0050.00190.0010.000.00
    R210.00640.00250.0050.00190.0010.0020.00
    R350.00600.00250.0050.00190.0010.00100.00
    R4100.00550.00250.0050.00190.0010.00200.00
    R5150.00500.00250.0050.00190.0010.00300.00
    79.2.

    Slope of fluorescence in Set A vs concentration of RNA standard gives m RNA+DNase(≈0.03)

    Slope of fluorescence in Set B vs concentration of RNA standard gives mRNA+RNase

    79.3.

    Calculate ρ

    80.

    Total RNA of the samples

    Where,

    RFUA and RFUC are the fluorescence in Tube A and Tube C of the same sample.

    RFUABlank and RFUCBlank are the fluorescence in Tube A and Tube C of the blank.

    81.

    DNA standard curve

    81.1.

    Concentrations of DNA standards in the microplate: Use measured DNA primary concentration instead of 500 ug/mL:

    ABCD
    595
    ABCD
    40960
    ABCDEFGH
    R1065025050190100
    D1106402505019010~10
    D2406102505019010~40
    D31005502505019010~100
    81.2.

    Slope of fluorescence in Set A vs concentration of DNA standard gives m DNA+DNase

    Slope of fluorescence in Set B vs concentration of DNA standard gives m DNA+RNase (≈0.12)

    81.3.

    Calculate δ

    82.

    Total DNA of the samples

    Where,

    RFUB and RFUC are the fluorescence in Tube B and Tube C of the same sample

    RFUBBlank and RFUCBlank are the fluorescence in Tube B and Tube C of the blank.

    83.

    Dilution factor=40

    If,

    • Sample is extracted by 1 mL extraction reagent
    • In Set 1, sample is diluted to 1/10
    • In Set 3, diluted by Tris and all working solutions to 250/950
    • In microplate, diluted by SG-II WS to 190/200